ORA-16191 PING[ARC2]: Heartbeat failed to connect to standby

mysql 搞代码 4年前 (2022-01-09) 20次浏览 已收录 0个评论

ORA-16191 PING[ARC2]: Heartbeat failed to connect to standby

随记一下今天遇到的一个问题吧。
环境介绍:
gi version:11.2.0.4.0
database version:11.2.0.4.0
Oracle linux:Linux Server release 6.4
RAC双节点ASM+restart-alone ASM
问题描述:
在duplicate 数据库后再启动standby 数据库的实时应用时出现在RAC1可以正常连接 standby,但RAC2无法连接,如下错误:
standby database:

Error 1017 received logging on to the standby
————————————————————
Check that the primary and standby are using a password file
and remote_login_passwordfile is set to SHARED or EXCLUSIVE,
and that the SYS password is same in the password files.
returning error ORA-16191
————————————————————
FAL[client, USER]: Error 16191 connecting to Rac for fetching gap sequence
Thu Apr 03 18:16:24 2014
RFS[6]: Assigned to RFS process 3836
RFS[6]: Opened log for thread 2 sequence 30 dbid -1867447592 branch 839537688
Archived Log entry 13 added for thread 2 sequence 30 rlc 839537688 ID 0x90b182d8 dest 2:
Thu Apr 03 18:16:26 2014
Media Recovery Log +FRA1/dg/archivelog/2014_04_03/thread_2_seq_30.288.843934585
Media Recovery Waiting for thread 2 sequence 31
Error 1017 received logging on to the standby
————————————————————
Check that the primary and standby are using a password file
and remote_login_passwordfile is set to SHARED or EXCLUSIVE,
and that the SYS password is same in the password files.
returning error ORA-16191
————————————————————
FAL[client, USER]: Error 16191 connecting to Rac for fetching gap sequence

RAC2错误如下:

PING[ARC2]: Heartbeat failed to connect to standby ‘DG’. Error 来&源gao@dai!ma.com搞$代^码%网is 16191.
Thu Apr 03 18:23:28 2014
Error 1017 received logging on to the standby
————————————————————
Check that the primary and standby are using a password file
and remote_login_passwordfile is set to SHARED or EXCLUSIVE,
and that the SYS password is same in the password files.
returning error ORA-16191
————————————————————
PING[ARC2]: Heartbeat failed to connect to standby ‘DG’. Error is 16191.
Thu Apr 03 18:24:29 2014
Error 1017 received logging on to the standby
————————————————————
Check that the primary and standby are using a password file
and remote_login_passwordfile is set to SHARED or EXCLUSIVE,
and that the SYS password is same in the password files.
returning error ORA-16191
————————————————————
PING[ARC2]: Heartbeat failed to connect to standby ‘DG’. Error is 16191.

问题排查:

检查remote_loging_passwordfile参数设置皆为EXCLUSIVE。其他参数没有任何可疑问题。

问题解决:

既然日志中提示认证出现问题,,且只有一个节点可以连接到standby database,那么将该节点的密码文件传到节点RAC2。


搞代码网(gaodaima.com)提供的所有资源部分来自互联网,如果有侵犯您的版权或其他权益,请说明详细缘由并提供版权或权益证明然后发送到邮箱[email protected],我们会在看到邮件的第一时间内为您处理,或直接联系QQ:872152909。本网站采用BY-NC-SA协议进行授权